No Blog Eletrônica de Potência você encontrará informações sobre teses,artigos,seminarios,congressos,tecnologias,cursos,sobre eletrônica potência. “TEMOS O DESTINO QUE MERECEMOS. O NOSSO DESTINO ESTA DE ACORDO COM OS NOSSOS MERITOS” ALBERT EINSTEIN. Imagination is more important than knowledge, for knowledge is limited while imagination embraces the entire world. EL FUTURO SE CONSTRUYE HOY,EL SUCESSO NO ES FRUTO DE LA CASUALIDAD,SE HUMILDE ,APRENDE SIEMPRE CADA DIA.
AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL
"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"
domingo, 29 de setembro de 2013
How to Use a AEMC 8335 Power Quality Analyzer
Review menu items of the 8335 as well as some new features of the PowerPad, which is replacing the AEMC 3945 power quality analyzer.
sexta-feira, 27 de setembro de 2013
quinta-feira, 26 de setembro de 2013
THREE–PHASE REDUCED SWITCH TOPOLOGIES FOR AC–DC FRONT–END AND SINGLE–STAGE CONVERTERS by Dunisha Wijeratne
THREE–PHASE REDUCED SWITCH TOPOLOGIES
FOR AC–DC FRONT–END
AND SINGLE–STAGE CONVERTERS
(THESIS FORMAT: Monograph)
by
Dunisha Wijeratne
Graduate Program in Engineering Science
Department of Electrical and Computer Engineering
A Thesis Submitted in Partial Fulfillment
of the Requirements for the Degree of
Doctor of Philosophy
The School of Graduate and Postdoctoral Studies
The University of Western Ontario
London, Ontario, Canada
©Dunisha
Abstract
Conventional three-phase AC-DC converters have two converter stages. They have a
front-end converter that converts the input AC voltage into an intermediate DC bus voltage
and a second, back-end converter that converts this DC bus voltage into the desired isolated
DC output voltage. The front-end converter also performs power factor correction (PFC) and
shapes the three-phase input currents so that they are nearly sinusoidal and in phase with the
three-phase input voltages. This allows the AC power source to be used in the most efficient
manner.
DOWNLOAD FULL THESIS
http://ir.lib.uwo.ca/cgi/viewcontent.cgi?article=2725&context=etd
RETIFICADOR TRIFASICO BIDIRECIONAL COM ALTO FATOR DE POTÊNCIA APLICADO A EXCITACÂO DE GERADORES SINCRONOS Rodrigo de Souza Santos UNIVERSIDADE FEDERAL SANTA CATARINA
RETIFICADOR TRIFASICO BIDIRECIONAL COM
ALTO FATOR DE POTÊNCIA APLICADO A
EXCITACÃO DE GERADORES SINCRONOS
Rodrigo de Souza Santos
Dissertac~ao submetida ao Programa
de Pos-Graduac~ao em Engenharia Eletrica
da Universidade Federal de Santa
Catarina para a obtencão do Grau de
Mestre em Engenharia Eletrica.
Orientador: Prof. Ivo Barbi, Dr. Ing.
UNIVERSIDADE FEDERAL DE SANTA CATARINA
DEPARTAMENTO DE ENGENHARIA ELETRICA BRASIL
DOWNLOAD FULL THESIS
http://www.ivobarbi.com/PDF/dissertacoes/DissertacaoRodrigoSantos.pdf
ALTO FATOR DE POTÊNCIA APLICADO A
EXCITACÃO DE GERADORES SINCRONOS
Rodrigo de Souza Santos
Dissertac~ao submetida ao Programa
de Pos-Graduac~ao em Engenharia Eletrica
da Universidade Federal de Santa
Catarina para a obtencão do Grau de
Mestre em Engenharia Eletrica.
Orientador: Prof. Ivo Barbi, Dr. Ing.
UNIVERSIDADE FEDERAL DE SANTA CATARINA
DEPARTAMENTO DE ENGENHARIA ELETRICA BRASIL
DOWNLOAD FULL THESIS
http://www.ivobarbi.com/PDF/dissertacoes/DissertacaoRodrigoSantos.pdf
RETIFICADOR TRIFÁSICO BUCK-BOOST DE ESTÁGIO ÚNICO Altamir Ronsani Borges
UNIVERSIDADE FEDERAL DE SANTA CATARINA
PROGRAMA DE PÓS-GRADUAÇÃO EM
ENGENHARIA ELÉTRICA
Altamir Ronsani Borges
RETIFICADOR TRIFÁSICO BUCK-BOOST DE ESTÁGIO ÚNICO
Tese submetida ao programa de
Pós Graduação em Engenharia
Elétrica da Universidade Federal
de Santa Catarina para a obtenção
do Grau de Doutor em Engenharia
Elétrica.
Orientador: Prof. Dr. Ivo Barbi
Florianópolis 2012.
RESUMO
Este trabalho apresenta uma nova topologia de retificador trifásico de
estágio único com característica Buck-Boost. Inicialmente é apresentada
uma revisão bibliográfica envolvendo as publicações mais relevantes na
área de estudo. Na sequencia são apresentadas a motivação para o
trabalho e as contribuições da Tese. A topologia proposta é apresentada
sendo descritas a sua origem e seus modos de operação de interesse. São
analisados então os modos de condução descontínua (MCD) e contínua
(MCC). No MCC são analisados os modos de operação Buck,
Buck+Boost e Boost. As etapas do estudo de cada modo de operação
compreendem a descrição das etapas de operação, análise teórica
estudos por simulação numérica, definição das equações de projeto e
resultados experimentais.
DOWNLOAD FULL THESIS
http://www.ivobarbi.com/PDF/Teses/Tese_Altamir.pdf
PROGRAMA DE PÓS-GRADUAÇÃO EM
ENGENHARIA ELÉTRICA
Altamir Ronsani Borges
RETIFICADOR TRIFÁSICO BUCK-BOOST DE ESTÁGIO ÚNICO
Tese submetida ao programa de
Pós Graduação em Engenharia
Elétrica da Universidade Federal
de Santa Catarina para a obtenção
do Grau de Doutor em Engenharia
Elétrica.
Orientador: Prof. Dr. Ivo Barbi
Florianópolis 2012.
RESUMO
Este trabalho apresenta uma nova topologia de retificador trifásico de
estágio único com característica Buck-Boost. Inicialmente é apresentada
uma revisão bibliográfica envolvendo as publicações mais relevantes na
área de estudo. Na sequencia são apresentadas a motivação para o
trabalho e as contribuições da Tese. A topologia proposta é apresentada
sendo descritas a sua origem e seus modos de operação de interesse. São
analisados então os modos de condução descontínua (MCD) e contínua
(MCC). No MCC são analisados os modos de operação Buck,
Buck+Boost e Boost. As etapas do estudo de cada modo de operação
compreendem a descrição das etapas de operação, análise teórica
estudos por simulação numérica, definição das equações de projeto e
resultados experimentais.
DOWNLOAD FULL THESIS
http://www.ivobarbi.com/PDF/Teses/Tese_Altamir.pdf
terça-feira, 24 de setembro de 2013
Vestimenta de proteção contra queimaduras por arco elétrico
Por Luiz K. Tomiyoshi
Vestimenta de proteção contra queimaduras por arco elétrico
As queimaduras por arcos elétricos representam uma parcela muito grande entre os ferimentos provocados por eletricidade em locais de trabalho. Apesar da seriedade e da importância vital que isso representa para os trabalhadores que executam serviços em eletricidade, este assunto tem recebido pouca atenção dos usuários em geral, quando comparado com outros perigos da eletricidade, como choques, incêndios e outros aspectos da segurança industrial.
É reconhecido que a tecnologia tem evoluído muito para preservar a integridade do equipamento ou da instalação, como proteção do sistema elétrico, detecção do arco interno, equipamentos resistentes a arco, entre outros. Essas tecnologias normalmente são aplicadas para proteção patrimonial e operacional da instalação na eventualidade de ocorrer falhas no sistema elétrico, segregando as partes afetadas ou confinando as consequências da falha em invólucros como painéis, de tal forma que não atinja as pessoas que eventualmente estiver na proximidade.
A maioria dos acidentes acontece quando o operador ou o eletricista precisa remover as barreiras de proteções como portas de painéis, instalar ou inserir e remover componentes operacionais como disjuntores com o equipamento energizado. Nestas situações, o trabalhador fica totalmente exposto ao perigo e a sua segurança só depende da prática segura e uso de Equipamento de Proteção Individual (EPI) adequado. É justamente nesta condição de trabalho que devemos ficar atentos providenciando proteção.
A energia liberada por arco elétrico é extremamente alta e pode causar ferimentos severos até a uma distância de três metros do ponto de falha nos equipamentos industriais de alta tensão mais comuns. O mesmo acontece no caso de distância menor, em equipamentos de baixa tensão.A energia liberada varia de acordo com a configuração do sistema elétrico e nível de curto-circuito disponível no ponto da falha.
O risco pode ser avaliado pela mesma sistemática adotada para dimensionamento e proteção dos equipamentos. As zonas de risco e o potencial podem ser determinados e calculados. Conhecendo a zona e o nível de risco, podemos estabelecer medidas de proteção por soluções de engenharia, tais como limitação de energia a um nível suportável, por meio do confinamento da energia e escolha adequada de Equipamentos de Proteção Individual (EPI).
Equipamento de Proteção Individual (EPI)
No Brasil, a Norma Regulamentadora nº 6, do Ministério do Trabalho e Emprego, estabelece as exigências legais para Equipamentos de Proteção Individual (EPI) para proteção dos trabalhadores contra riscos suscetíveis de ameaçar a segurança e a saúde no trabalho. Nesta NR não está explicita a necessidade de proteção contra arcos elétricos, mas estabelece que o EPI deve proteger os trabalhadores contra agentes térmicos para cabeça, face, membro superior e inferior e corpo inteiro. O arco elétrico, em uma falha, é um agente térmico comparado à solda elétrica a arco. A diferença é que nos serviços em eletricidade, os arcos ocorrem por falha, liberando energia muito superior a de uma máquina de solda e é um risco suscetível de ameaça à segurança e à saúde do trabalhador. Logo, o trabalhador deve ser protegido pelo EPI da mesma maneira que protegemos os soldadores.
Nos Estados Unidos e na Europa, em função da necessidade e da obrigatoriedade legal para proteção contra os efeitos térmicos do arco elétrico, foram desenvolvidos normas para verificar e determinar o desempenho dos tecidos e vestimentas utilizados como EPIs pelas entidades como a ASTM, nos Estados Unidos, a CENELEC, na Europa e a IEC, com abrangência internacional. Descreveremos adiante as particularidades de cada norma.
Equipamento elétrico à prova de arco
As normas técnicas internacionais e brasileiras prescrevem que os equipamentos elétricos devem ser dimensionados e construídos para suportar os esforços mecânicos e térmicos em casos de curto-circuito sem danificar o equipamento. No caso de equipamentos à prova de arco, todo o material da combustão deve ser direcionado para cima para não atingir o trabalhador, as portas e as coberturas de proteção não devem abrir para que não haja rajadas de fragmentos, o arco não deve provocar furos no painel, a integridade do aterramento deve ser mantida e a amostra de tecido deve ser colocada a certa distância, na posição vertical e horizontal para que não inflame. Esta condição é encontrada em situações normais de operação, em que o equipamento é mantido fechado, porém, para manutenção ou inspeção e verificação, muitas vezes precisamos abrir a porta, remover as coberturas de proteção, remover ou inserir componentes, como disjuntores ou gavetas de CCMs, alterando toda a condição de segurança estabelecida pelas normas. Portanto, mesmo para equipamentos à prova de arco, o trabalhador especializado fica exposto ao risco.
ARTIGO COMPLETO
http://www.osetoreletrico.com.br/web/component/content/article/58-artigos-e-materias-relacionadas/149-vestimenta-de-protecao-contra-queimaduras-por-arco-eletrico.html
segunda-feira, 23 de setembro de 2013
ELECTRONIQUE DE PUISSANCE
ELECTRONIQUE DE PUISSANCE
Ch1 – HACHEUR
Ch2 – THYRISOR
Ch3 – REDRESSEMENT NON COMMMANDE
Ch4 – REDRESSEMENT COMMANDE
Ch5 – GRADATEUR
Ch6 – ONDULEUR
DOWNLOAD
http://mpeea.free.fr/data/trotech/ELECTRONIQUE DE PUISSANCE09.pdf
Ch1 – HACHEUR
Ch2 – THYRISOR
Ch3 – REDRESSEMENT NON COMMMANDE
Ch4 – REDRESSEMENT COMMANDE
Ch5 – GRADATEUR
Ch6 – ONDULEUR
DOWNLOAD
http://mpeea.free.fr/data/trotech/ELECTRONIQUE DE PUISSANCE09.pdf
domingo, 22 de setembro de 2013
Power Quality Harmonics Analysis and Real Measurements Data
Power Quality Harmonics Analysis and Real Measurements Data
Edited by Gregorio Romero Rey and Luisa Martinez Muneta, ISBN 978-953-307-335-4, Hard cover, 278 pages, Publisher: InTech, Chapters published November 23, 2011 under CC BY 3.0 licenseDOI: 10.5772/699
Download for Free
PDF file (zipped) 10.19 MB
WEBSITE ORIGINALhttp://www.intechopen.com/books/power-quality-harmonics-analysis-and-real-measurements-data
Electromagnetism for electronic engineers
Electromagnetism for electronic engineers - The
book is, first and foremost, about electromagnetism, and any book which
covers this subject must deal with its various laws. You will found
beginning with electrostatics, then moving to current electricity, the
magnetic effects of currents, electromagnetic induction and
electromagnetic waves. -Free Download here
WEBSITE ORIGINAL
http://blog.educationjelly.com/downloads/
WEBSITE ORIGINAL
http://blog.educationjelly.com/downloads/
Énergie : peut-on changer les règles du jeu ? ENERGIA PODEMOS MUDAR AS REGRAS
Conférence Cyclope du 20/03/2013 par Henri Safa, Direction de l'énergie nucléaire
INTERESANTE Y EXCELENTE EXPOSICION DE UN TEMA DE ACTUALIDAD PERMANENTE EL DESAFIO DE LA ENERGIA EN EL MUNDO,ENERGIA HIRAULICA,ENERGIA DEL CARBON,ENERGIA NUCLEAR,ENERGIA DEL GAS,ENERGIA PRODUCIDA POR EL PETROLEO,CONSECUENCIAS POLITICAS,ECONOMICAS,AMBIENTALES DEL ACTUAL USO DE LA ENERGIA,PROBLEMAS A RESOLVER 2010-2050.
sexta-feira, 20 de setembro de 2013
quinta-feira, 19 de setembro de 2013
segunda-feira, 16 de setembro de 2013
Low harmonic content three-phase-to-DC-conversion using AC-side switches and discontinuous conduction mode utor: Carlton, Dan Degree Doctor of Philosophy - PhD Program Electrical and Computer Engineering THE UNIVERSITY OF BRITISH COLUMBIA
Arquivos deste item
|
A new DSP controlled bi-directional DC/DC converter system for inverter/charger applications Swingler, Andrew Duncan Degree Doctor of Philosophy - PhD Program Electrical and Computer Engineering THE UNIVERSITY OF BRITISH COLUMBIA
Título: | A new DSP controlled bi-directional DC/DC converter system for inverter/charger applications | |
Autor: | Swingler, Andrew Duncan | |
Degree | Doctor of Philosophy - PhD | |
Program | Electrical and Computer Engineering | |
Copyright Date: | 2003 | |
URI: | http://hdl.handle.net/2429/16121 | |
Arquivos | Tamanho | Formato | Descrição | Visualização | |||||
---|---|---|---|---|---|---|---|---|---|
ubc_2004-902749.pdf | 10.69Mb | Adobe Portable Document Format | Visualizar/ |
DOWNLOAD FULL
http://www.mediafire.com/?syvrf7shxpx0b6a
OUTPUT VOLTAGE CONTROL OF A FOUR-LEG INVERTER BASED THREE-PHASE UPS BY MEANS OF STATIONARY FRAME RESONANT FILTER BANKS BY EYYUP DEMİRKUTLU
OUTPUT VOLTAGE CONTROL
OF A FOUR-LEG INVERTER BASED THREE-PHASE UPS
BY MEANS OF STATIONARY FRAME RESONANT FILTER BANKS
BY
EYYUP DEMİRKUTLU
A THESIS SUBMITTED TO
THE GRADUATE SCHOOL OF NATURAL AND APPLIED SCIENCES
OF
MIDDLE EAST TECHNICAL UNIVERSITY
DOWNLOAD FULL THESIS
http://www.mediafire.com/?wa85c49r88sxeg3
domingo, 15 de setembro de 2013
Design and Control of an Inverter for Photovoltaic Applications by Søren Bækhøj Kjær
Dissertation submitted to the Faculty of Engineering and Science at Aalborg University
in partial fulfillment of the requirements for the degree of Doctor of Philosophy (Ph.D.)
in Electrical Engineering.
The public defence took place on May 27, 2005. The assessment committee was:
• Professor Vassilios G. Agelidis, Murdoch University, Australia
• Professor Jorma Kyyrä, Helsinki University of Technology, Finland
• Associate Professor Remus Teodorescu, Aalborg University (Chairman)
DOWNLOAD FULL THESIS
http://www.mediafire.com/?vg53s61fnwzzw6a
Modular Power Electronic Converters in the Power Range 1 to 10 kW by Pawel Klimczak Aalborg University, Denmark Institute of Energy Technology
Abstract
Thanks to CO2 emission reduction policies and increasing prices of fossil fuels a
significant growth in field of sustainable energy sources (SES) is being observed
during last decade. A government support and take-off projects in Europe and US
shall ensure an increasing trend in future too. Some of SES based plants , like
hydro-, geothermal-, biofuel-plants, use synchronous generators directly connected
to the grid. But some other SES technologies, like fuel cell or photovoltaic, require
a power electronic converter between the energy source and the load or the grid.
Work presented in this thesis concentrates on dc-dc non-isolated converters suitable
for high voltage gain applications, like uninterruptible power supply (UPS) and
some of sustainable energy sources. A special attention is on reduction of power
losses and efficiency improvements in non-isolated dc-dc step-up converters.
DOWNLOAD FULL THESIS
http://www.mediafire.com/?8ammjw81mer0bl0
Thanks to CO2 emission reduction policies and increasing prices of fossil fuels a
significant growth in field of sustainable energy sources (SES) is being observed
during last decade. A government support and take-off projects in Europe and US
shall ensure an increasing trend in future too. Some of SES based plants , like
hydro-, geothermal-, biofuel-plants, use synchronous generators directly connected
to the grid. But some other SES technologies, like fuel cell or photovoltaic, require
a power electronic converter between the energy source and the load or the grid.
Work presented in this thesis concentrates on dc-dc non-isolated converters suitable
for high voltage gain applications, like uninterruptible power supply (UPS) and
some of sustainable energy sources. A special attention is on reduction of power
losses and efficiency improvements in non-isolated dc-dc step-up converters.
DOWNLOAD FULL THESIS
http://www.mediafire.com/?8ammjw81mer0bl0
Non-isolated Single Phase Uninterruptible Power Supply (UPS) System Muhammad Aamir and Hee-Jun Kim Dept. of Electronics, Electrical, Control, and Instrumentation Engineering, Hanyang University, Korea
Non-isolated Single Phase Uninterruptible
Power Supply (UPS) System
Muhammad Aamir and Hee-Jun Kim
Dept. of Electronics, Electrical, Control, and Instrumentation Engineering, Hanyang University, Korea
Abstract-- In this paper, a high performance single phase
transformer-less online uninterruptable power supply (UPS)
is proposed. The use of the bidirectional buck-boost
converter with high conversion ratio not only reduces the
number of batteries but also ensures a transformer-less
system. The rectifier has capability of power factor
correction and provides regulated DC link voltage whereas
the inverter provides a regulated sinusoidal output voltage
to the load. In order to control the transient effect, efficient
control scheme is adopted in the system. The overall
efficiency of the system is improved with significant
reduction in size and weight of the system due to decrease
number of batteries. Qualitative analysis and experimental
results obtained with a 500VA prototype shows a normal
efficiency of over 94% and an input power factor of over 99%.
DOWNLOAD FULL PAPER
http://www.mediafire.com/?w2twja6ndyui660
Abstract-- In this paper, a high performance single phase
transformer-less online uninterruptable power supply (UPS)
is proposed. The use of the bidirectional buck-boost
converter with high conversion ratio not only reduces the
number of batteries but also ensures a transformer-less
system. The rectifier has capability of power factor
correction and provides regulated DC link voltage whereas
the inverter provides a regulated sinusoidal output voltage
to the load. In order to control the transient effect, efficient
control scheme is adopted in the system. The overall
efficiency of the system is improved with significant
reduction in size and weight of the system due to decrease
number of batteries. Qualitative analysis and experimental
results obtained with a 500VA prototype shows a normal
efficiency of over 94% and an input power factor of over 99%.
DOWNLOAD FULL PAPER
http://www.mediafire.com/?w2twja6ndyui660
sábado, 14 de setembro de 2013
sexta-feira, 13 de setembro de 2013
quinta-feira, 12 de setembro de 2013
terça-feira, 10 de setembro de 2013
An Overview on Amorphous Core Transformers Man Mohan Electrical Engineering Department
Abstract
In this paper, an amorphous core transformer is highlighted. Configuration of amorphous C-core and its magnetisation characteristic (B-H) are described. Factors affecting the design are also discussed as a comparison with a conventional transformer. It is concluded that, advantages with amorphous core transformers are - low core losses, low magnetising current, less zero sequence current, less noise, higher efficiency and longer life; however the disadvantages are higher inrush current, more harmonic problem, bigger size and higher initial cost. The problem of third harmonic may be eliminated by adopting zig-zag connection in place of star connection. Purpose of this article is to provide a knowledge base about amorphous core transformers, to students of transformer design, by discussing some necessary issues. __________________________________________________________________________________________ LINK
http://www.mediafire.com/?1kicbyeispkdgqe
Amorphous-Core Transformer with Copper Winding Versus Aluminium Winding-A Comparative Study
Amorphous core transformers are in developing stage; they are considered as energy efficient transformers. Cost of amorphous core transformer is about 20 to 30 per cent higher than that of a conventional transformer of same KVA rating. Among several parameters, cost of winding material is a parameter, on which cost of a transformer depends. In a transformer, the cost of winding material may be up to 28 per cent of overall cost of a transformer. Cost of a transformer may be reduced if aluminum winding is adopted in place of copper winding; aluminum is lighter in weight and cheaper in price, compared to copper winding. Here, a comparative study is presented for an amorphous core transformer with copper winding versus aluminum winding, in terms of cost efficiency and mechanical forces. It has been found that, if aluminum winding is adopted for 400KVA amorphous core transformer, the cost reduces, efficiency improves and mechanical forces.
DOWNLOAD FULL PAPER
http://www.ejournalofscience.org/archive/vol2no4/vol2no4_4.pdf
domingo, 8 de setembro de 2013
UNIVERSIDADE FEDERAL DO RIO GRANDE DO SUL ESCOLA DE ENGENHARIA DEPARTAMENTO DE ENGENHARIA ELÉTRICA MÁRCIO MOURA DE MATTOS PROJETO DE DIPLOMAÇÃO ESTUDO DO FATOR K EM TRANSFORMADORES A SECO BRASIL
RESUMO
Este trabalho tem por finalidade apresentar um
estudo sobre harmônicas suas causas e
suas conseqüências em instalações elétricas.
Será realizado um estudo da decomposição dos
sinais de energia elétrica através da decomposição da Séria de Fourier,
a partir da qual serão mostrada e calculada as diferente ordens das harmônicas
Será dada ênfase nas conseqüências
dessas em transformadores a seco.
Onde será calculado o Fator K em seus dois modos o
modo da UL e o modo que é assumido por muito autores como sendo o Fator K normalizado.
.
Esse estudo está diretamente
relacionado com a temperatura de funcionamento do
transformador e sua vida útil.
Para exemplificar o estudo será
mostrada a constituição do
transformador a seco fabricado
pela empresa SIEMENS, que recebe o nome de GEAFOL.
ARTICULO COMPLETO
http://www.lume.ufrgs.br/bitstream/handle/10183/65619/000864745.pdf?sequence=1
ARTICULO COMPLETO
http://www.lume.ufrgs.br/bitstream/handle/10183/65619/000864745.pdf?sequence=1
“Cálculo das Perdas Técnicas dos Transformadores de Distribuição, Operando em Ambiente Não-Senoidal” Luciano Dos Santos UNESP UNIVERSIDADE ESTADUAL PAULISTA CAMPUS DE ILHA SOLTEIRA PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA BRASIL
Dissertação submetida à Faculdade de
Engenharia de Ilha Solteira – UNESP - como
parte dos requisitos exigidos para a obtenção
do título de
Mestre em Engenharia Elétrica.
RESUMO
Este trabalho está direcionado à implementação de uma modelagem que venha possibilitar a
realização dos cálculos das perdas técnicas no cobre do transformador trifásico de distribuição
operando em condições não-senoidais, através da utilização do valor médio de Distorção
Harmônica Total de Corrente drenada por suas cargas. Essa implementação visa facilitar a
obtenção dos valores das perdas técnicas para múltiplas unidades transformadoras. Para atingir o
objetivo mencionado, realizou-se um ensaio em curto-circuito através de ensaios experimentais
aplicadas em uma unidade transformadora trifásica de distribuição com 15 kVA de capacidade. A
fonte trifásica de alimentação utilizada na atividade proporciona o ajuste de tensão e da
freqüência, possibilitando obter os valores de resistências CA dos enrolamentos do transformador
para diferentes ordens harmônicas. Com o propósito de validar esta nova proposta, foi realizada
uma análise confrontando-se os dados obtidos através da modelagem proposta neste trabalho e de
uma outra bastante difundida pela literatura atual. Os cálculos foram efetuados utilizando-se
dados de distorções harmônicas de correntes oriundas de medições de ramais de distribuição.
Através da comparação dos resultados obtidos é possível verificar a validade da modelagem proposta.
TESIS COMPLETA
http://www.feis.unesp.br/Home/departamentos/engenhariaeletrica/pos-graduacao/167-dissertacao_luciano_dos_santos.pdf
RESUMO
Este trabalho está direcionado à implementação de uma modelagem que venha possibilitar a
realização dos cálculos das perdas técnicas no cobre do transformador trifásico de distribuição
operando em condições não-senoidais, através da utilização do valor médio de Distorção
Harmônica Total de Corrente drenada por suas cargas. Essa implementação visa facilitar a
obtenção dos valores das perdas técnicas para múltiplas unidades transformadoras. Para atingir o
objetivo mencionado, realizou-se um ensaio em curto-circuito através de ensaios experimentais
aplicadas em uma unidade transformadora trifásica de distribuição com 15 kVA de capacidade. A
fonte trifásica de alimentação utilizada na atividade proporciona o ajuste de tensão e da
freqüência, possibilitando obter os valores de resistências CA dos enrolamentos do transformador
para diferentes ordens harmônicas. Com o propósito de validar esta nova proposta, foi realizada
uma análise confrontando-se os dados obtidos através da modelagem proposta neste trabalho e de
uma outra bastante difundida pela literatura atual. Os cálculos foram efetuados utilizando-se
dados de distorções harmônicas de correntes oriundas de medições de ramais de distribuição.
Através da comparação dos resultados obtidos é possível verificar a validade da modelagem proposta.
TESIS COMPLETA
http://www.feis.unesp.br/Home/departamentos/engenhariaeletrica/pos-graduacao/167-dissertacao_luciano_dos_santos.pdf
domingo, 1 de setembro de 2013
REDUCTION DES PERTES A VIDE DES TRANSFORMATEURS DE DISTRIBUTION PAR UTILISATION DE RUBANS AMORPHES by Malick MOUHAMAD
THESE DE DOCTORAT
DE L’ECOLE NORMALE SUPERIEURE DE CACHAN
Présentée par
Malick MOUHAMAD
pour obtenir le grade de
DOCTEUR DE L’ECOLE NORMALE SUPERIEURE DE CACHAN
Domaine :
ELECTRONIQUE – ELECTROTECHNIQUE – AUTOMATIQUE
REDUCTION DES PERTES A VIDE DES TRANSFORMATEURS DE DISTRIBUTION PAR UTILISATION DE RUBANS AMORPHES
Thèse présentée et soutenue à Cachan le 28/02/2012
Abstract
This PhD dissertation deals with the application of amorphous ribbons in distribution transformer cores in order to reduce network losses.
The material is an alloy from iron, boron and silicon compounds. The first results on the material reveal a good physicochemical compatibility with tested transformer dielectric fluids. It should be noted these materials possess a far longer life than the transformer itself.
The potential for reducing losses from distribution transformers is considered as one element of EU and national strategies on energy efficiency. Losses generated through amorphous transformers are twice less than conventional ones.
Amorphous ribbon units represent a significant new advance in transformer technology and losses reduction. The investment, put to purchase the product, can be easily gained by the capitalisation of losses. The return can be achieved in 10 to 12 years, depending on the purchase price.
It is expected that a transformer will be subjected to a number of short-circuits during its service life, but sooner or later one such event will cause some slight winding movement, and the ability of the transformer to resist further short-circuits will then be severely reduced.
Amorphous metal distribution transformers (AMDT) is no exception and they should be able to resist electrodynamic forces during short-circuit test and match ERDF specifications. In fact, during SC, extreme electrodynamic forces cause the windings to deform and this shape deformity creates a lot of shear stress on amorphous cores which lead to break-up of some ribbons. The active part of an amorphous transformer should be strong enough to resist these stresses.
In fact, the behaviour of the core materials under short circuit currents depends especially on the know-how of manufacturers who can outline electrodynamic stress inside transformers. Concept design and processes have been improved in order to provide reliable devices but the task is not completely done yet.
Short-circuit withstand is one of the most important aspects which will approve this technology.
DOWNLOAD FULL THESIS
http://innovation.edf.com/fichiers/fckeditor/Commun/Innovation/theses/TheseMouhamad.pdf
DE L’ECOLE NORMALE SUPERIEURE DE CACHAN
Présentée par
Malick MOUHAMAD
pour obtenir le grade de
DOCTEUR DE L’ECOLE NORMALE SUPERIEURE DE CACHAN
Domaine :
ELECTRONIQUE – ELECTROTECHNIQUE – AUTOMATIQUE
REDUCTION DES PERTES A VIDE DES TRANSFORMATEURS DE DISTRIBUTION PAR UTILISATION DE RUBANS AMORPHES
Thèse présentée et soutenue à Cachan le 28/02/2012
Abstract
This PhD dissertation deals with the application of amorphous ribbons in distribution transformer cores in order to reduce network losses.
The material is an alloy from iron, boron and silicon compounds. The first results on the material reveal a good physicochemical compatibility with tested transformer dielectric fluids. It should be noted these materials possess a far longer life than the transformer itself.
The potential for reducing losses from distribution transformers is considered as one element of EU and national strategies on energy efficiency. Losses generated through amorphous transformers are twice less than conventional ones.
Amorphous ribbon units represent a significant new advance in transformer technology and losses reduction. The investment, put to purchase the product, can be easily gained by the capitalisation of losses. The return can be achieved in 10 to 12 years, depending on the purchase price.
It is expected that a transformer will be subjected to a number of short-circuits during its service life, but sooner or later one such event will cause some slight winding movement, and the ability of the transformer to resist further short-circuits will then be severely reduced.
Amorphous metal distribution transformers (AMDT) is no exception and they should be able to resist electrodynamic forces during short-circuit test and match ERDF specifications. In fact, during SC, extreme electrodynamic forces cause the windings to deform and this shape deformity creates a lot of shear stress on amorphous cores which lead to break-up of some ribbons. The active part of an amorphous transformer should be strong enough to resist these stresses.
In fact, the behaviour of the core materials under short circuit currents depends especially on the know-how of manufacturers who can outline electrodynamic stress inside transformers. Concept design and processes have been improved in order to provide reliable devices but the task is not completely done yet.
Short-circuit withstand is one of the most important aspects which will approve this technology.
DOWNLOAD FULL THESIS
http://innovation.edf.com/fichiers/fckeditor/Commun/Innovation/theses/TheseMouhamad.pdf