Performance Improvement of PWM Converter-Inverter System for AC Supplied Electric Train -HYUNGCHUL KIM -CHUNGBUK NATIONAL UNIVERSITY



ABSTRACT
Domestically in 1994, both Gwacheon and Bundang line used the GTO converter/inverter system instead of the resistance control system, which started active research on AC supplied vehicle.[3] Addition to this, introduction of high-speed railway vehicles such as KTX and tilting train has developed interest about PWM converter-inverter system and its control method.[9] PWM converter which converts AC power into DC power has been used to maintain the sinusoidal current waveform and unity power factor in AC side. This means that the AC current controller of PWM converter has to produce very low AC current tracking error and no phase delay even though the load changes abruptly.[10-17] The PWM converter system with feedback controller is generally constructed with double feedback loop, which consists of an inner AC current-feedback loop and an outer DC voltage-feedback loop.[7][22] These feedback loops are usually designed with PI controller, but the close interconnection between the loops complicates the frequency analysis to the design controller. When a digital controller is used, the control performance is limited to a certain value due to the low sampling rate. Therefore, the system characteristics depend on various situation, and the gain tuning of each PI controller has been basing on trial and error method conventionally considering switching frequency, sampling frequency, parameter variation, and etc. This research proposes a robust digital current controller for a single phase AC/DC PWM converter in electric train under two main considerations. One is that overall system keeps very low AC current tracking error without any phase delay over the different load conditions, and the other is that the digital controller is designed at a fixed sampling rate. First, we design a continuous-time controller for a continuous-time plant and then discretize the controller with the given sampling frequency. This kind of process has some disadvantages because its fidelity depends on the sampling rate and the discrete method, but it has sufficient and valuable design method in developing continuous-time linear systems. The error-space feedback control scheme to carry out the robust AC current tracking is used, which is well known as an analytic state-feedback method to give a controller the ability to track a non-decaying input perfectly and to reject a non-decaying disturbance such as a sinusoidal input. And to achieve the time response requirements, the characteristic ratio assignment (CRA) is introduced, which has the ability to deal directly with the overshoot and speed of step response in an all-pole system with arbitrary order.[25] This method is based on certain relationships between the coefficients of characteristic polynomial and the transient responses. The CRA design formulates a model matching method whose reference model is selected from a target polynomial. In this paper, the state feedback gains are determined by the CRA instead of the pole-placement method.
LINK
http://www.mediafire.com/view/sxc1dk8mmveiyzp/Performance_Improvement_of_PWM_Converter-Inverter_System_for_AC_Supplied_Electric_Train.pdf

ON THE PERSPECTIVES OF WIDE-BAND GAP POWER DEVICES IN ELECTRONICS BASED POWER CONVERSION FOR RENEWABLE SYSTEMS SAMUEL VASCONCELOS ARAUJO KASSEL UNIVERSITY



LINK ORIGINAL
http://www.uni-kassel.de/upress/online/frei/978-3-86219-486-5.volltext.frei.pdf

Analysis and Comparison of Power Electronic Converters with Electronic Isolation Por Kazanbas, Mehmet



LINK
https://books.google.com.br/books?id=jn_NBgAAQBAJ&lpg=PA153&ots=qPcwif2Tyz&dq=THESIS%20GERMANY%20POWER%20ELECTRONICS%20CONVERTER%20KASSEL%20UNIVERSITY&hl=pt-BR&pg=PP1#v=onepage&q&f=false

quinta-feira, 5 de março de 2015

"TEORÍA DE CONJUNTOS Y TEMAS AFINES" - Seymour Lipschutz



SURFANDO EN LA INTERNET ENCONTRE ESTE LIBRO EN LA PAGINA WEB
http://matealdia.blogspot.com.br/2012/04/teoria-de-conjuntos-y-temas-afines.html

LINK  skydrive   : http://sdrv.ms/Qmz8Yu

A Study on the Design of 300W Power Factor Correction using Interleaving Method-TAE-WOO KIM DEPT. OF ELECTRICAL ENGINEERING GRADUATE SCHOOL CHANGWON NATURAL UNIVERSITY






ABSTRACT
Generally, critical conduction mode(CRM) boost PFC converter used low power level and continuous conduction mode(CCM) boost PFC converter is used in medium or high power application. Critical conduction mode boost PFC converter can be used in medium or high power application by using interleaving technical. Interleaved critical conduction mode boost PFC converter can reduce current ripple for higher system reliability and smaller buck capacitor and EMI filter size. In this paper, The design of 300W PFC preconverter using interleaving method which can improve light-load efficiency and have many advantage, is presented.