AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS  DO MAL"

“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO.”

“Sixty years ago I knew everything; now I know nothing; education is a progressive discovery of our own ignorance. Will Durant”

https://picasion.com/
https://picasion.com/

quarta-feira, 12 de novembro de 2014

A Study on Improving Efficiency of High-frequency Switching Hybrid Inverter Circuit in Grid-connected Photovoltaic Power Generation Heo, Chan-Yoo Department of Electrical Engineering Graduate School Soongsil University





ABSTRACT
A Study on Improving Efficiency of High-frequency Switching Hybrid Inverter Circuit in Grid-connected Photovoltaic Power Generation Heo, Chan-Yoo Department of Electrical Engineering Graduate School Soongsil University
Supervised by Professor Jeon, Hee-Jong
 The various problems of Energy pluralism by new and renewable energy technique development is in progress mainly from advanced countries due to recent global warming by environmental change and fossil energy resources depletion. And major area of fuel cell, photovoltaic and wind power generation are actively in progress from many types of new and renewable energy. Photovoltaic power system stores the direct current resource generated from photovoltaic module into battery, and converts this into alternating current to use. Photovoltaic power generation uses solar for its energy resource, which does not need fuel, and the equipment has long life since it has no moving parts or heat engine. Also, it is more convenient in operation and maintenance than other existing power generation methods. But, it has higher unit cost than existing power generating methods, and need wide area to install solar cell module to use certain amount of electric power since its energy density is scarce. In addition, it has weak point of close influence by environmental condition such as weather condition. All sections of the photovoltaic power system from raw material to the grid connection are important, but the photovoltaic power inverter, which relates the stable power to the grid or can supply powerto individual load, can be regarded as one of the most important section. The generated power is of no use if the inverter does not make regular output even though a lot of power is generated from the photovoltaic array. The criteria for evaluating the photovoltaic inverter's performance is the power conversion efficiency of the inverter. For domestic photovoltaic power system, the booster converter's efficiency is around 99[%], the inverter efficiency is around 94[%], and studies are in progress to improve inverter efficiency. The Grid connected inverters in photovoltaic PCS(Power Conditioning System) have different efficiency according to their switching methods. 3 Level PWM switching type circuit has half the frequency than the circuit composed of 2 Level PWM, and has improved efficiency because of less switching loss. In general, photovoltaic PCS mainly use IGBT components. But the hybrid circuit composed of MOSFET and IGBT components is considered to improve efficiency even more by improving reverse recovery time and loss by IGBT's tailing current. In this paper, it is intended to prove that the high-frequency switching inverter circuit with MOSFET has improved efficiency than 3 Level circuit with all IGBT components through simulation and 3[kW] PCS hardware.

terça-feira, 11 de novembro de 2014

Non-isolated Single Phase Uninterruptible Power Supply (UPS) System Muhammad Aamir Department of Electronics, Electrical, Control, and Instrumentation Engineering Hanyang University





ABSTRACT
In this thesis, a high performance single phase transformer-less online uninterruptible power supply (UPS) is proposed. The use of the bidirectional buck-boost converter with high conversion ratio not only reduces the number of batteries but also ensures a transformer-less system. The rectifier has capability of power factor correction and provides regulated DC link voltage whereas the inverter provides a regulated sinusoidal output voltage to the load. In order to control the transient effect, efficient control scheme is adopted in the system. The overall efficiency of the system is improved with significant reduction in size and weight of the system due to decrease number of batteries. Qualitative analysis and experimental results obtained with a 500VA prototype shows a normal efficiency of over 94% and an input power factor of over 99%.
LINK
https://copy.com/GDccLCWhNLzUqDJ0

Filtering Methods for DC Link Voltage Control of Common-neutral-type Transformerless Single-phase UPS KIM JI-SU DEPARTAMENT OF ELECTRICAL ENGINEERING GRADUATE SCHOOL KONKUK UNIVERSITY


ABSTRACT

UPS is largely divided into passive-standby, line-interactive, and double-conversion types. Commonly a double-conversion type is used at a site requiring a high reliability. These days, important factors of UPS are high efficiency, low input current distortion, high input power factor, small cabinet size and low price. In this thesis, a common-neutral type transformerless UPS is proposed. A proposed UPS is composed of PFC with 1-switch voltage doubler strategy, half-bridge inverter, separate battery charger and separate battery discharger. PFC with 1-switch voltage doubler strategy and half-bridge inverter are configured as commom-neutral type so that they can convert power without input and output transformer. Therefore input and output transformers can be removed, so the efficiency can be improved and cabinet size can be reduced. Also advantage of PFC with 1-switch voltage doubler strategy and half-bridge inverter is that they need a small number of switching devices so they can simplify driving circuitry and reduce the price. Advantage of separate battery charger and separate battery discharger is that they can make battery voltage lower than DC link voltage so they can reduce the quantity and cost of battery which is an important part of UPS. PI controller was used as voltage controller and current controller of PFC. In order to compensate imbalance of positive and negative DC link voltages, imbalance voltage PI controller was used. In order to compensate leading effect of input current, duty feedforward method was used. Several methods to eliminate 120Hz ripple component in DC voltage feedback were compared with each other. Moving Average resulted in better performance than other methods. Half-bridge was used as inverter circuit. In order to achieve stable static output voltage and improve dynamic characteristic multi-loop control method was used. Finally, the value of proposed UPS was confirmed in the method of simulation and experiment.

segunda-feira, 10 de novembro de 2014

Study on Management Standards of Total Harmonics Distortion(THD) measured from UPS Jeong,Unho Department of Electrical and Electronic Engineering Graduate School,Dongshin University




Study on Management Standards of Total
Harmonics Distortion(THD) measured from UPS
Jeong,Unho
Department of Electrical and Electronic Engineering
Graduate School,Dongshin University
(SupervisorbyProfessor:Ph.D.Kim,Dong-Min)

The purpose of this paper is to describe UPS(Uninterruptible Power
Supply) in a comprehensive measure THD(Total Harmonic Distortion)
and compared with domestic and international management standards
in harmonics, harmonics reduction measures by analyzing the
appropriate UPS technology. Harmonics generated by the UPS
measurements of national standards was confirmed appropriate, UPS
comprehensive harmonic currents measured range THD-I limits for
national standards, the reference by KSC 4310, THD-V for domestic
not based on the site was confirmed. Therefore,The IEEE(Institute of
Electrical and Electronics Engineers)Std.519 is applied in this paper as
a reference for domestic standards on THD-V limits management.In
recent years,according to integration of KSC standards into IEC,UPS
standards are being revised as KSC IEC 62040,butthere are still no
regulations for THD-V and THD-IaboutUPS causing confusions in
some aspects.
LINK
http://www.mediafire.com/view/1bahx2wgay96n9a/Study_on_Management_Standards_of_Total_Harmonics_Distortion(THD)_measured_from_UPS.pdf

Electronic measurement in nanotechnology and microelectronics Dyakonov V.


Title: Electronic measurement in nanotechnology and microelectronics
Author: Athos AA Dyakonov V.
Publisher: DMK Press
Year: 2011
Pages: 688
Format: PDF
Size: 47.0 MB
ISBN: 50,2
Quality: Excellent

Russia's first monograph on the most advanced electronic and electrical radio measurements and measuring instruments used in research, testing and test equipment and systems, microelectronics and nanotechnology. For the first time in detail the means of measurement applied in a large-scale microelectronic production and instruments leading to their developing and manufacturing firms: Keithley, Tektronix, Agilent Technologies, LeCroy, R & S and others. Particular attention is paid to the analysis and generation of test signals, measurement of their parameters in small and micro time measured by ultra low currents and voltages, impedance analysis and immittance circuits, measurement of static and dynamic characteristics of semiconductor devices and integrated circuits and others. It is the largest survey of contemporary foreign and domestic instruments in the market of Russia and the world. For engineers, scientists, graduate students, teachers and students of universities and technical universities and classical types.
LINK
http://www.mediafire.com/view/80tjucbcmp2mi90/Electronic_measurement_in_nanotechnology_and_microelectronics.pdf