No Blog Eletrônica de Potência você encontrará informações sobre teses,artigos,seminarios,congressos,tecnologias,cursos,sobre eletrônica potência. “TEMOS O DESTINO QUE MERECEMOS. O NOSSO DESTINO ESTA DE ACORDO COM OS NOSSOS MERITOS” ALBERT EINSTEIN. Imagination is more important than knowledge, for knowledge is limited while imagination embraces the entire world. EL FUTURO SE CONSTRUYE HOY,EL SUCESSO NO ES FRUTO DE LA CASUALIDAD,SE HUMILDE ,APRENDE SIEMPRE CADA DIA.
AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL
"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"
domingo, 14 de julho de 2019
Managing Personal Communications & Presentation : Samsung Mobile Marketing-Yonsei University Sean Watts EIC professor Marketing-South Korea
Principles of International Marketing-PART2-Professor Sean Watts, Korea's Harvard- Yonsei University
Principles of International Marketing-PART1-Professor Sean Watts, Korea's Harvard- Yonsei University
Sean can be contacted at : https://www.facebook.com/wattssean
sábado, 13 de julho de 2019
A Study on the Transient Operation Algorithm of 30kW Micro-grid based on CVCF Inverter Hu Dong, Lee Department of Electronic and Electrical Engineering The Graduate School Korea University of Technology and Education
A Study on the Transient Operation Algorithm of 30kW Micro-grid based on CVCF Inverter Hu Dong, Lee Department of Electronic and Electrical Engineering The Graduate School Korea University of Technology and Education
ABSTRACT
The phenomenon of energy sinking can be occurred if the output of renewable energy sources is larger than customer loads. In this case, voltage of CVCF battery could be increased rapidly according to the condition of SOC(State of Charge) and blackout could be occurred due to shut-down of CVCF inverter, at carbon free island micro-grid based on the CVCF(Constant Voltage & Constant Frequency) inverter. In order to overcome these problems, this paper proposes a transient operation algorithm in CVCF based micro-grid which in advance prevents shut-down of CVCF inverter during the energy sinking. And also this paper proposes the modeling of 30kW micro-grid including CVCF inverter, PV system, customer load using PSCAD/EMTDC S/W and implements test device of 30kW micro-grid. From the results of 30kW micro-grid modeling and test device based on the proposed algorithm, it is confirmed that CVCF based micro-grid can properly prevent shut-down of CVCF inverter according to SOC and battery voltage of CVCF inverter when energy sinking is occurred.
Keyword : Carbon free island Micro-grid, CVCF inverter, Energy sinking, Transient operation
LINK:https://www.mediafire.com/file/aakhn6edjiqxuuq/A_Study_on_the_Transient_Operation_Algorithm_of_30kW_Micro-grid_based_on_CVCF_Inverter.pdf/file
UNIFIED POWER QUALITY CONDITIONER: DESIGN, SIMULATION AND EXPERIMENTAL ANALYSIS PhD THESIS-Ahmet TEKE DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ÇUKUROVA UNIVERSITY
UNIFIED POWER QUALITY CONDITIONER: DESIGN, SIMULATION AND EXPERIMENTAL ANALYSIS PhD THESIS-Ahmet TEKE DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ÇUKUROVA UNIVERSITY
ABSTRACT
Power quality (PQ) problem can be defined as the deviations of the voltage and/or current from the nominal sine wave. PQ problems generally concern with voltage sags/swells and harmonic currents. Custom Power (CP) devices that mitigate these power quality problems have gained more attention in the recent decades. Unified Power Quality Conditioner (UPQC) is one of the CP devices and it mitigates both load current and supply voltage problems, simultaneously. In this study, UPQC and a new topology of UPQC namely OPEN UPQC are designed, modeled and setup experimentally to mitigate voltage sag/swells and harmonic currents. UPQC consists of Dynamic Voltage Restorer (DVR) and Active Power Filter (APF). An improved voltage compensation controller and new sag/swell detection method based on Enhanced Phase Locked Loop (E-PLL) are presented for DVR. Traditional Instantaneous Reactive Power Theory (IRPT) is optimized for APF control algorithm to compensate harmonic load current under unbalanced and distorted supply voltages. Digital Signal Processor based 6 kVA, 230Vline-lineUPQC and OPEN UPQC prototypes have been developed for laboratory tests. UPQC and OPEN UPQC with proposed controller algorithms effectively compensates the sag/swell in supply voltage by keeping the load voltage amplitude at 0.9-1 per unit and eliminates the load current harmonics by keeping supply current at 5%
Key Words: Unified Power Quality Conditioner, OPEN UPQC, Custom Power, Active
Power Filter, Dynamic Voltage Restorer.
LINK: https://www.mediafire.com/file/wtcckymm7e4qn7i/8411-CONDICIONADOR_POTENCIA.pdf/file
Assinar:
Postagens (Atom)