Analysis, Design, and Control of a Single-Phase Single-Stage Grid-Connected Transformerless Solar Inverter by Manisha Verma - Department of Electrical and Computer Engineering -Concordia University Montreal, Quebec, Canada.


 Analysis, Design, and Control of a Single-Phase Single-Stage Grid-Connected Transformerless Solar Inverter Manisha Verma A Thesis In the Department of Electrical and Computer Engineering Presented in Partial Fulfillment of the Requirements For the Degree of Master of Applied Science at Concordia University Montreal, Quebec, Canada. June 2019

ABSTRACT

 Analysis, Design, and Control of a Single-Phase Single-Stage Grid-Connected Transformerless Solar Inverter Manisha Verma As energy utilization is increasing with the rise in the world’s power demand, the traditional energy sources are depleting at a high pace. It has led to attention drawn towards inexhaustible energy resources. There is a huge augmentation in the power generation from renewable energy sources (RES) like wind, solar, hydropower, biomass, etc. to reduce the stress on conventional energy sources like fossil fuels, oil, gas, etc. There has been a steep increase in interest for wind and solar energy systems. PV energy has been growing swiftly in the past two decades which made it most demanded power generation system based on RES. This worldwide requirement for solar energy has led to an immense amount of innovation and development in the Photovoltaic (PV) market. The Conventional grid-connected PV inverter was either with DC/DC converter or without DC/DC converter. These inverters were isolated using a transformer either on the grid (AC) side as a low-frequency transformer or as a highfrequency transformer on the DC side. Elimination of the transformer leads to a galvanic connection between the grid and PV module. This gives rise to the flow of leakage current which is disastrous for the system when it exceeds a specific value. Thus, minimization of this leakage current after the removal of the transformer has been an interesting topic explored by many researchers. Many topologies have been proposed targeting reduction in this leakage current either by 1.) Directly connecting the PV negative with neutral of utility grid or 2.) Disconnecting the PV panel side from AC side. This generally involved addition of more switches or diodes or supplementary branches to disconnect during the freewheeling period. Generally, the above-mentioned ways lead to a reduction in efficiency due to increased losses or complex circuitry. The motivation of this thesis is to design a transformerless inverter for single-phase PV grid-tied system with a smaller number of devices and still has minimum ground current. It discusses the prevailing inverter topologies in detail and then explains the modes of operation of the proposed inverter. A simple control strategy has been derived and passive elements of the inverter are designed. The simulation results presented have validated the theoretical claims. The experimental results which are similar to simulation results are evidence that the proposed topology is suitable for PV grid-tied systems. Also, the dynamic modeling of the inverter has been done to derive the plant transfer function. Then, the Proportional Resonant (PR) controller has been designed to ensure the flow of sinusoidal current into the grid with zero steady-state error and constant sinusoidal grid voltage irrespective of load change. The simulation and experimental results achieved high performance which makes this topology successful and promising for grid-tied PV systems.

LINK: https://spectrum.library.concordia.ca/985562/1/Verma_MASc_F2019.pdf

Control Design of a Single-Phase DC/AC Inverter for PV Applications by Haoyan Liu - University of Arkansas, Fayetteville


 Control Design of a Single-Phase DC/AC Inverter for PV Applications A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Electrical Engineering by Haoyan Liu

Harbin University of Science and Technology Bachelor of Engineering in Automation, 2012 May 2016 University of Arkansas

Abstrac

This thesis presents controller designs of a 2 kVA single-phase inverter for photovoltaic (PV) applications. The demand for better controller designs is constantly rising as the renewable energy market continues to rapidly grow. Some background research has been done on solar energy, PV inverter configurations, inverter control design, and hardware component selection. Controllers are designed both for stand-alone and grid-connected modes of operation. For standalone inverter control, the outer control loop regulates the filter capacitor voltage. Combining the synchronous frame outer control loop with the capacitor current feedback inner control loop, the system can achieve both zero steady-state error and better step load performance. For grid-tied inverter control, proportional capacitor current feedback is used. This achieves the active damping needed to suppress the LCL filter resonance problem. The outer loop regulates the inverter output current flowing into the grid with a proportional resonant controller and harmonic compensators. With a revised grid synchronization unit, the active power and reactive power can be decoupled and controlled separately through a serial communication based user interface. To validate the designed controllers, a scaled down prototype is constructed and tested with a digital signal processor (DSP) TMS320F28335.

LINK:https://core.ac.uk/download/pdf/80559559.pdf

quinta-feira, 24 de setembro de 2020

A new high-efficiency single-phase transformerless PV inverter topology Tamás Kerekes, Member, IEEE, Remus Teodorescu, Senior Member, IEEE, Pedro Rodríguez, Member, IEEE, Gerardo Vázquez, Student Member, IEEE, Emiliano Aldabas, Member, IEEE







A new high-efficiency single-phase transformerless PV inverter topology

Tamás Kerekes, Member, IEEE, Remus Teodorescu, Senior Member, IEEE, Pedro Rodríguez, Member, IEEE, Gerardo Vázquez, Student Member, IEEE, Emiliano Aldabas, Member, IEEE

ABSTRACT: There is a strong trend in the photovoltaic (PV) inverter technology to use transformerless topologies in order to acquire higher efficiencies combining with very low ground leakage current. In this paper a new topology, based on the H- Bridge with a new AC bypass circuit consisting in a diode rectifier and a switch with clamping to the DC midpoint is proposed. The topology is simulated and experimentally validated and a comparison with other existing topologies is performed. High conversion efficiency and low leakage current is demonstrated.

I INTRODUCTION Photovoltaic inverters become more and more widespread within both private and commercial circles. These grid connected inverters convert the available direct current supplied by the photovoltaic (PV) panels and feed it into the utility grid. According to the latest report on installed PV power, during 2007 there has been a total of 2.25GW of installed PV systems, out of which the majority (90%) has been installed in Germany, Spain, USA and Japan. At the end of 2007 the total installed PV capacity has reached 7.9 GW of which around 92% is grid connected [1].

There are two main topology groups used in case of grid connected PV systems and they are: with and without galvanic isolation [2]. Galvanic isolation can be on the DC side, in the form of a high frequency DC-DC transformer or on the grid side in the form of a big-bulky AC transformer. Both of these solutions offer the safety and advantage of galvanic isolation, but the efficiency of the whole system is decreased, due to power losses in these extra components. In case the transformer is omitted the efficiency of the whole PV system can be increased with an extra 1-2%. The most important advantages of transformerless PV systems can be observed in Fig. 1, like: higher efficiency, smaller size and weight compared to the PV systems that have galvanic isolation (either on the DC or AC side). 1 Fig. 1 has been made from the database of more than 400 commercially available PV inverters, presented in a commercial magazine about PV systems [3]. Transformerless inverters are represented by the dots (Transformerless), while the triangles represent the inverters that have a low-frequency transformer on the grid side (LF-transformer) and last the stars represent the topologies including a high-frequency DC-DC transformer (HF-transformer), adding a galvanic isolation between the PV and grid. The conclusion drawn from these graphs is that transformerless inverters have higher efficiency, smaller weight and size than their counterparts with galvanic separation. Transformerless PV inverters use different solutions to minimize the leakage ground current and improve the efficiency of the whole system, an issue that has previously been treated in many papers [4]-[11].

LINK: http://seer.upc.edu/material/ficheros_publicaciones/26552ZRV_PV_Inverter.pdf

terça-feira, 8 de setembro de 2020

A Digital Control System for UPS Systems with Smart Grid Capability-Author Mardani Boroujeni, Fatemeh-Faculty Schulich School of Engineering- Institution University of Calgary

 


A Digital Control System for UPS Systems with Smart Grid Capability by Fatemeh Mardani Boroujeni
 
UNIVERSITY OF CALGARY
A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF SCIENCE GRADUATE PROGRAM IN ELECTRICAL ENGINEERING CALGARY, 
ALBERTA AUGUST, 2019.

  Abstract 

Smart grids have recently become the center of attention for modernizing the grid system. In future smart-grids, energy storage systems are one of the key components, which can complement intermittent renewable energy sources and in turn increase reliability and eciency of the grid system. Modern Uninterruptible Power Supply (UPS) systems can provide storage capacity for future smart grids since they usually include batteries. UPS systems can also provide instant electrical power to sensitive equipment and grid during various events such as brownout, power failures, spikes, voltage surges, EMI/RF noise, and frequency variations.

Future UPS systems require to have much better dynamics in order to deal with transients. The control system of UPS systems mainly determines their dynamical performance and transient response. The existing state-of-the-art UPS control systems are based on linear PI controllers for the most part. Thus, current UPS systems usually show a sluggish transient response and they are not suited for future smart grid applications where instant power is required to maintain the system.

In this thesis, new UPS systems with improved transient response are proposed. The proposed UPS system utilities a new controller that is able to improve the dynamic performance and allows for various smart grid functionalities. The proposed control system is based on the adaptive control theory, which adaptively changes the controller's parameters based on the UPS operating conditions. Furthermore, the proposed control system isolates the double-frequency ripple from the battery in the normal/charging mode as well as in the backup/discharging mode. Therefore, the new UPS system is well-suited for single-phase systems utilizing lithium-ion battery as storage. Mathematical analysis, simulation, and experimental results are presented to verify the performance of the proposed control system and demonstrate its superior performance.

LINK:https://prism.ucalgary.ca/bitstream/handle/1880/110715/ucalgary_2019_mardaniboroujeni_fatemeh.pdf?sequence=2&isAllowed=y

quarta-feira, 2 de setembro de 2020

Conception et optimisation d’ Alimentations Sans Interruption-THÈSE Pour obtenir le grade de DOCTEUR DE LA COMMUNAUTE UNIVERSITE GRENOBLE ALPES Spécialité : Génie Electrique--Présentée par « Mahmoud IBRAHIM »


 


Conception et optimisation d’Alimentations Sans Interruption THÈSE Pour obtenir le grade de DOCTEUR DE LA COMMUNAUTE UNIVERSITE GRENOBLE ALPES

Spécialité : Génie Electrique Arrêté ministériel : 7 août 2006 Présentée par « Mahmoud IBRAHIM »

Thèse dirigée par Jean-Paul FERRIEUX Co-encadrée par David FREY et Pierre LEFRANC préparée au sein du Laboratoire de Génie Électrique de Grenoble (G2Elab) dans l'École Doctorale Électronique, Électrotechnique, Automatique et Traitement du Signal (EEATS)

Résumé La conception des Alimentations Sans Interruption (ASI) a fait l’objet d’améliorations successives ces dernières années afin d’atteindre des niveaux de rendement avoisinant les 95% tout en minimisant leur encombrement. L’utilisation massive de l’électronique de puissance pour ces systèmes conduit à y concentrer tous les efforts de conception pour augmenter à la fois le rendement et la densité de puissance. Les développements constants en électronique de puissance offrent au concepteur des multitudes d’options, parmi elles, les topologies de puissance multi-niveaux et/ou entrelacées pour réduire le volume des composants passifs, les nouvelles technologies des matériaux semi-conducteurs avec l’introduction des composants grand gap, ainsi que l’avancée technologique sur les matériaux utilisés dans les composants passifs. Le choix entre ces options est un compromis pour atteindre les objectifs prédéfinis, particulièrement lorsque d’autres contraintes apparaissent pour limiter l’espace des solutions possibles, notamment l’aspect thermique, les limites technologiques ou les contraintes CEM.

Ces travaux proposent la mise en oeuvre de dimensionnements par optimisation multiobjectifs de l’ensemble du convertisseur avec toutes ses contraintes. Ceci offre un outil rapide pour comparer les différentes possibilités de conception optimale capable de quantifier le gain apporté au convertisseur par les différentes solutions. Pour ce faire, les différents choix topologiques et technologiques ont été traités par le développement de modèles multiphysiques acceptant des paramètres d’entrée discrets. Ainsi, les convertisseurs optimisés répondent naturellement aux contraintes industrielles cadrées par des catalogues de fournisseurs spécifiques.

Pour ce faire, nous avons commencé par dresser les différentes contraintes énergétiques imposées sur l’ASI dans son environnement. L’identification des solutions adaptées à sa conception est réalisée à travers un état de l’art des recherches dans le domaine de l’électronique de puissance. Des modèles génériques des structures de puissance, ainsi que des modèles multi-physiques discrets des composants sont ensuite développés à la base des approches analytiques assurant le bon compromis entre précision et rapidité de calcul. Finalement, une méthodologie d’optimisation multi-objectif et multi contraintes est réalisé sur l’ensemble des solutions pour quantifier les performances atteintes par chacune d’elles. Des travaux expérimentaux nous ont été indispensables pour valider les modèles et les solutions optimales. Sur la base des résultats d’optimisation un convertisseur PFC de 4.2kW/L a été construit est ses performances ont été validées.

LINK:  https://tel.archives-ouvertes.fr/tel-01401407/document