AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS  DO MAL"

“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO.”

“Sixty years ago I knew everything; now I know nothing; education is a progressive discovery of our own ignorance. Will Durant”

Mostrando postagens com marcador INVERTER. Mostrar todas as postagens
Mostrando postagens com marcador INVERTER. Mostrar todas as postagens

domingo, 14 de dezembro de 2014

Design of Robust Controller for Single-Phase Double-Conversion UPS System Seung-Beom Lim, Young-Min Seol, Sang-Hoon Kim, Jin-Woo Lee, and Soon-Chan Hong Dankook University, Korea, Kangwon National University, Korea





Design of Robust Controller for Single-Phase
Double-Conversion UPS System

Seung-Beom Liml, Young-Min Seo, Sang-Hoon Kim, Jin-Woo Lee, and Soon-Chan Hongl
 Dankook University, Korea,  Kangwon National University, Korea, Doowon Technical College,
Koreabus1327@hotmail.com, maniyan@nate.com, kshoon@kangwon.ac.kr, jinwoo@doowon.ac.kr, schong@dku.edu

Abstract-UPS is largely divided into passive-standby, line interactive,
and double-conversion types. In general, a double conversion
type is used at a site requiring a high reliability. The
main function of the double-conversion UPS is providing the
constant voltage, constant frequency, regardless of the linear or
non-linear load and variation of the load. In this paper, the
robust controller of the single phase double-conversion UPS is
designed and its performance is verified by both simulations and
experimentation.


segunda-feira, 16 de dezembro de 2013

Parallel Operation of Three-Phase Four wire UPS using Droop Control ( Hyunseob Kim․Jungho Han․Joong-Ho Song )

Parallel Operation of Three-Phase Four wire UPS using Droop Control

* Main author:Dept. of Railway Electrical and
Signaling Engineering, Seoul National
University of Science and Technology,
Candidate of MS
** Corresponding author:Dept. of Electrical and
Information Engineering, Seoul National
University of Science and Technology,
Professor
Tel:02-970-6415, Fax:02-978-2754
E-mail:joongho@seoultech.ac.kr
 Abstract
A new droop control method which can be applied to 3-phase 4-wire uninterruptible power supply is
proposed in this paper. The droop control method for parallel operation is very attractive one as UPS
parallel operation can be carried out without any data communication devices provided among UPS
systems connected, but it reportedly shows a PnP(plug-and-play) problem. A basic reason why a
circulating current could flow among parallel-connected UPS systems is clearly investigated as well
when droop-controlled-ups systems are operated in the manner of PnP. The proposed algorithm is
deduced from the investigated result and is basically structured to keep a balanced frequency and
balanced voltage profile against power variation. This paper shows that balanced parallel operation of
droop control method can be obtained under unbalanced load as well as balanced load conditions .when PnP operation is needed and load change occurs.
LINK
http://www.koreascience.or.kr/article/ArticleFullRecord.jsp?cn=JMJGCE_2013_v27n4_88

https://www.mediafire.com/?gyedgrq3fd38alx

segunda-feira, 15 de março de 2010

REVIEW OF PV INVERTER TECHNOLOGIES FOR PRACTICAL IMPLEMENTATION








REVIEW OF PV INVERTER TECHNOLOGIES FOR PRACTICAL
IMPLEMENTATION

Kuo-Lung Chai, Yue-Chun Lin, Jing-Fong Hsu, and Ying-Yu Tzou
Power Electronics IC Design and DSP Control Lab.,
Dept. of Electrical and Control Engineering, National Chiao Tung Univ., Hsinchu, Taiwan