ABSTRACT
The distributed generation has been increased significantly.However,there
are some problems caused by distributed generation such as reverse power flow,
voltage fluctuation and harmonics when it is connected to the distribution
system.Also,we observed the voltage fluctuation in the distribution system
with distributed generation.This paper analyzes the voltage fluctuation according
to the output fluctuation of distributed generation and presents a study on
D-STATCOM which is a shuntdevice used to compensate powerquality on
distribution lines using real-time simulator.The modeling ofthe distribution
system with distributed generation is modeled by using SIMULINK software.
FULL THESIS
LINK1
ftp://dcollection.skku.edu/dcoll/data/service/000000038/000000038744.pdf
No Blog Eletrônica de Potência você encontrará informações sobre teses,artigos,seminarios,congressos,tecnologias,cursos,sobre eletrônica potência. “TEMOS O DESTINO QUE MERECEMOS. O NOSSO DESTINO ESTA DE ACORDO COM OS NOSSOS MERITOS” ALBERT EINSTEIN. Imagination is more important than knowledge, for knowledge is limited while imagination embraces the entire world. EL FUTURO SE CONSTRUYE HOY,EL SUCESSO NO ES FRUTO DE LA CASUALIDAD,SE HUMILDE ,APRENDE SIEMPRE CADA DIA.
AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL
“GRAÇAS A DEUS PELA VIDA,PELA MINHA FAMÍLIA,PELO TRABALHO.PELO PÃO DE CADA DIA,POR NOS PROTEGER DO MAL”
“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO”

https://picasion.com/


sexta-feira, 6 de junho de 2014
Output Filter Design of Grid-Connected Inverter for High Power Offshore Wind Power System
Output Filter Design of Grid-Connected Inverter for High Power Offshore Wind Power System
The output filter design for high power grid-connected inverter of offshore wind-turbine has many limitations such as low switching frequency, allowable DC-voltage, and the component volume and weight. In addition, the injected harmonic current into the grid is constrained by various grid connection requirements. This paper compared and weighed with several harmonic regulations and suggested the optimal design procedure of the output filter compliance with the grid code using spectrum analysis of inverter output voltage that contains harmonics. In this paper, the output filter of grid connected inverter for 7MVA offshore wind power system is designed to meet the BDEW harmonic currents limits and the IEEE 519-1992 requirements. The performance of the designed output filter is validated by extensive simulations using Matlab/Simulink.
FULL THESIS
https://www.mediafire.com/?z4tizq8in557vih
quarta-feira, 4 de junho de 2014
PWM RECTIFIER WITH ACTIVE FILTERING PHD THESIS M.SC. MARIUSZ CICHOWLAS WARSAW UNIVERSITY OF TECHNOLOGY
WARSAW UNIVERSITY OF TECHNOLOGY
FACULTY OF ELECTRICAL ENGINEERING
INSTITUTE OF CONTROL AND INDUSTRIAL ELECTRONICS
PHD. THESIS
M.SC. MARIUSZ CICHOWLAS
PWM RECTIFIER WITH ACTIVE FILTERING
FULL THESIS HERE:
http://www.isep.pw.edu.pl/icg/pdf/phd/mariusz_cichowlas.pdf