No Blog Eletrônica de Potência você encontrará informações sobre teses,artigos,seminarios,congressos,tecnologias,cursos,sobre eletrônica potência. “TEMOS O DESTINO QUE MERECEMOS. O NOSSO DESTINO ESTA DE ACORDO COM OS NOSSOS MERITOS” ALBERT EINSTEIN. Imagination is more important than knowledge, for knowledge is limited while imagination embraces the entire world. EL FUTURO SE CONSTRUYE HOY,EL SUCESSO NO ES FRUTO DE LA CASUALIDAD,SE HUMILDE ,APRENDE SIEMPRE CADA DIA.
AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL
"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"
quinta-feira, 26 de fevereiro de 2015
Design and Control of a DC Collection Grid for a Wind Farm-LENA MAX-Department of Energy and Environment CHALMERS UNIVERSITY OF TECHNOLOGY Goteborg, Sweden 2009
Design and Control of a DC Collection Grid for a Wind Farm LENA MAX Department of Energy and Environment Chalmers University of Technology
Abstract
In this thesis, the internal DC collection grid for a wind farm is investigated regarding the design, losses and dynamic operation for both normal operating conditions and for different fault conditions. The main advantage for the DC collection grid is the considerably lower weight of the 1 kHz transformers in the DC/DC converters compared to the equivalent 50 Hz transformers. For a wind farm with 48 2.3 MW wind turbines, and a DC/DC converter in each turbine as well as a main DC/DC converter for the whole wind farm, the losses for the DC system are 3 % of the transferred power, which is similar to the losses of a corresponding AC collection grid. For the dynamic control of the wind farm, the DC/DC converters control the power flow in the wind farm and thereby also the voltage levels for the 1.5 kV DC link in the turbine as well as for the 32 kV DC collection bus. For the limited bandwidth resulting from the switching frequency 1 kHz and the maximum voltage deviations of 5 % for the DC voltages, the required capacitances are 152 mF for the DC link in the wind turbine and 16 mF for the DC bus, both giving a stored energy corresponding to 74 ms transferred rated power. In the case of a fault in the connecting main grid, the output power from the wind farm must be decreased. Here, assuming that the excess power is dissipated in each turbine, the detection of the fault as well as the disconnection and the reconnection of the wind farm are investigated. The requirements for the HVDC link to avoid over voltages during a grid fault are stated and it is also shown that the reconnection can be done within 14 ms, which is well within the time specified in existing grid codes. Further, the behavior of the system during internal faults for the DC bus is investigated. Methods for detecting and finding the location of the faults are determined, and it is shown that a faulted part can be disconnected and the non-faulted parts reconnected within 300 ms without using fully rated DC breakers. Index Terms: DC/DC converter, DC collection grid, loss evaluation, wind energy, control design, fault handling. iii
LINK FULL PAPER
http://publications.lib.chalmers.se/records/fulltext/101249/101249.pdf
A Simple procedure to evaluate the efficiency and power density of power conversion topologies for offshore wind turbines Rene Barrera-Cardenas,∗ , Marta Molinas Department of Electric Power Engineering, Norwegian University of Science and Technology, NO-7491, Trondheim, Norway
Abstract
The prospective development of the offshore wind energy conversion system is mainly promoted by demand for higher efficiency and power density. This paper describes a simple procedure to calculate the efficiency and power density of power conversion systems for offshore wind turbines. The proposed method can be used as starting point into the linear design process to calculate the losses in semiconductors and transformer as well as the volume of main elements. With the losses and volumes, efficiency and power density can be calculated. In order to illustrate the evaluation procedure, the reduced matrix converter with single-phase transformer is considered like example topology. The Efficiency-Power-density Pareto Front is obtained for a set of design parameters. The methodology is eminently suitable for comparison of power converter with different topologies. © 2012 Published by Elsevier Ltd.
LINK FULL PAPER
http://www.sciencedirect.com/science/article/pii/S1876610212011423
domingo, 22 de fevereiro de 2015
sábado, 21 de fevereiro de 2015
SYLLABUS DE CURSOS GRADUAÇÃO ENGENHARIA ELETRÔNICA UNIVERSIDADE FEDERAL SANTA CATARINA BRASIL
LISTA COMPLETA DE TODOS OS CURSOS ENGENHARIA ELETRÕNICA UNIVESIDADE FEDERAL DE SANTA CATARINA DURANTE OS 10 SEMESTRES
LINK
http://cagr.sistemas.ufsc.br/relatorios/curriculoCurso?curso=235
Assinar:
Postagens (Atom)