AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS  DO MAL"

“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO.”

“Sixty years ago I knew everything; now I know nothing; education is a progressive discovery of our own ignorance. Will Durant”

https://picasion.com/
https://picasion.com/

sábado, 19 de agosto de 2017

TRANSFORMADORES DE POTÊNCIA-TEORIA E APLICAÇÕES TÓPICOS ESSENCIAIS DANIEL DA SILVA NOGUEIRA


TRANSFORMADORES DE POTÊNCIA-TEORIA E APLICAÇÕES TÓPICOS ESSENCIAIS

AUTORES: DANIEL DA SILVA NOGUEIRA,DIEGO PRANDINO ALVES

DEPARTAMENTO DE ENGENHARIA ELÉTRICA  DA ESCOLA POLITÉCNICA DA UNIVERSIDADE DE RIO DE JANEIRO BRASIL

LINK ORIGINAL LIVRE NA WEB:
http://monografias.poli.ufrj.br/monografias/monopoli10001033.pdf


quarta-feira, 16 de agosto de 2017

terça-feira, 15 de agosto de 2017

A Study on Control and Grid Synchronization for a Threephase Grid-connected Inverter in Distributed Generation Systems - Lai Ngoc Bao -Dept. of Electrical and Information Engineering The Graduate School Seoul National University of Science and Technology


Abstract
A Study on Control and Grid Synchronization for a Three-phase Gridconnected Inverter in Distributed Generation Systems Lai Ngoc Bao (Supervisor Kim, Kyeong-Hwa) Dept. of Electrical and Information Engineering The Graduate School Seoul National University of Science and Technology

This thesis presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. The primary challenge associated with the gridconnected inverter in distributed generation (DG) systems is to maintain the harmonic contents in output current below the specified values even when the grid is subject to uncertain disturbances such as harmonic distortion. To address such a challenge, an improved current control scheme is proposed for a grid-connected inverter, in which the fundamental and harmonic currents are independently controlled by a PI decoupling controller and a predictive basis controller, respectively. The controller design approach is based on the model decomposition principle, where the measured inverter currents and grid voltages are split into the fundamental and harmonic currents using moving average filters (MAFs). Furthermore, to detect the grid angular displacement and frequency with better accuracy even in the presence of the grid voltage disturbances, the MAF is also introduced to construct an enhanced phase-lock loop (PLL) scheme. Theoretical analyses as well as comparative simulations results prove that the proposed control scheme adequately compensates the abnormalities caused by the grid voltage disturbances with fast transient response. To validate the feasibility of the proposed control scheme, the iientire control algorithm is implemented on a 2 kVA three-phase grid-connected inverter system using 32-bit floating-point DSP TMS320F28335. As a result, the proposed scheme is an attractive way to control a grid-connected inverter under adverse grid conditions.

LINK
http://www.mediafire.com/file/6bwc5529rb2b24u/grid.pdf

Leakage Inductance Determination for Transformers with Interleaving of Windings R. Doebbelin and A. Lindemann Institute of Electric Power Systems, Otto-von-Guericke-University Magdeburg, Germany


Leakage Inductance Determination for Transformers with
Interleaving of Windings
R. Doebbelin and A. Lindemann
Institute of Electric Power Systems, Otto-von-Guericke-University Magdeburg, Germany

Abstract| A diversity of formulas is given in literature for leakage inductance calculation
of transformers with interleaving of windings. In the paper, the meaning of included terms and
details of the application for concentric and pie windings transformers shall be discussed. Consid-
ering the limitation of common formulas to magnetically symmetric transformers an alternative
approach shall be demonstrated, which enables leakage inductance prediction also in the case of
transformers with magnetically asymmetric arrangements of windings.

LINK VIEW FULL TEXT:
ttp://www.mediafire.com/file/m116cldykkbcvqc/Vol6No6Page527to531.pdf




segunda-feira, 14 de agosto de 2017

NO-BREAK SOLAR OFF-GRID HIBRIDO LANÇAMENTO NA EXPOSEC 2017 SÃO PAULO BRASIL




Potências: 5.000 a 10.000W

Alta confiabilidade: Controle microprocessado DSP, combinando tecnologia SPWM e chaveamento de potência em alta frequência
Modo de operação selecionável: Prioridade armazenamento ou fornecimento de energia Prevenção de danos: por atenuação PID garantindo a vida útil plena dos painéis fotovoltaicos
 Gerenciamento de baterias: Carregador com três estágios, reduzindo o tempo de recarga e protegendo contra descarga profundal de baterias
Alimentação: AC: com sincronismo on-line, minimizando o tempo de transfência garantindo o fornecimento de energia à carga
Seleção automática: de frequência (60/50Hz)
Comunicação inteligente: RS232 ou USB (SNMP opcional)