AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL

GIF 1 GIF 2

“GRAÇAS A DEUS PELA VIDA,PELA MINHA FAMÍLIA,PELO TRABALHO.PELO PÃO DE CADA DIA,POR NOS PROTEGER DO MAL”

“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO”

https://picasion.com/
https://picasion.com/

terça-feira, 23 de setembro de 2025

Small-Signal Stability Analysis and Optimization of Grid-Forming Permanent-Magnet Synchronous-Generator Wind Turbines by Guanghui Li ,Runqi Han ,Zhen Li,Bin Lui,


Small-Signal Stability Analysis and Optimization of Grid-Forming Permanent-Magnet Synchronous-Generator Wind Turbines by Guanghui Li 1,Runqi Han 2,*,Bin Liu 2,*ORCID andZhen Li 3ORCID National Key Laboratory of Renewable Energy Grid-Integration, China Electric Power Research Institute, Beijing 100192, China College of Artificial Intelligence, China University of Petroleum (Beijing), Beijing 102249, China School of Automation and Key Laboratory for Intelligent Control & Decision on Complex Systems, Beijing Institute of Technology, Beijing 100081, China 

 Abstract Due to the ability to improve the low-inertia characteristics of power systems and offer reliable voltage and frequency support, grid-forming permanent-magnet synchronous-generator wind turbines (PMSG-WTs) based on virtual synchronous-generator (VSG) technology are emerging se the direction for future developments. Previous studies on the small-signal stability of grid-forming PMSG-WTs that connect to the grid usually simplify them into grid-connected grid-side converters (GSC), potentially leading to errors in stability analyses. Therefore, this paper considers the machine-side converter (MSC) control and establishes impedance models for grid-forming PMSG-WTs. Based on the sensitivity calculation of controller parameters using symmetric difference computation based on zero-order optimization, the impact of the internal controller on outside impedance characteristics is quantitatively analyzed. Additionally, an optimization method to enhance the stability of a hybrid wind farm by adjusting the ratio of grid-forming and grid-following wind turbines is proposed.

Stability analysis of small signals under different ratios of grid-following to grid-forming converters sent via flexible DC delivery-Feng Li1, Zhijie Li2,*, Shuangmian Yang1, Jinyu Wang2 and Yibo Zhang1 1TBEA Science & Technology Investment Co., Ltd., Tianjin, 301700, China 2College of Electrical Engineering, Xi'an Jiaotong University, Xian, Shanxi, 712000, China


 Stability analysis of small signals under different ratios of grid-following to grid-forming converters sent via flexible DC delivery Feng Li1, Zhijie Li2,*, Shuangmian Yang1, Jinyu Wang2 and Yibo Zhang1 1TBEA Science & Technology Investment Co., Ltd., Tianjin, 301700, China 2College of Electrical Engineering, Xi'an Jiaotong University, Xian, Shanxi, 712000, China 

 Abstract: Under the "dual carbon" strategy, frequent wide-band grid oscillations caused by grid-following converters as the interface for renewable energy integration have become common. Existing studies suggest that the addition of grid-forming converters can address this issue, but few explain the reasons from a stability mechanism perspective. Additionally, most studies overlook the interaction between converters and sending-end converter stations. This paper first conducts sequential impedance modeling. Then, based on impedance network analysis, it examines the impact of sending-end converter stations on stability assessment. Finally, by adjusting the grid-following/grid-forming ratio, Nyquist curves under different ratios are generated to analyze the mechanism by which grid-forming converters enhance gridfollowing small-signal stability. Corresponding simulation models are also developed for validation.

A Study on Internal Fault Simulation Methods for 345kV Autotransformers 345kV 단권변압기 내부고장 모의방법에 관한 연구 Jong-Kee Choi ․ You-Jin Lee ․ Jun-Ho Cho ․ Young-Hun Kwon ․ Ji-Hwan Park ․ Young-Hun Jang 최종기† ․ 이유진* ․ 조준호** ․ 권영훈*** ․ 박지환§ ․ 장영훈


 

SCHEMATIC DIAGRAM THREE-PHASE PHASE FAILURE DETECTOR CIRCUIT AND THREE-PHASE PHASE SEQUENCE-Simulation and Analysis Using PSpice


 



segunda-feira, 22 de setembro de 2025

Power Transfer Stability Analysis of Grid Forming Converters-Seong-Jeon Lee ․ Joosik Kwak ․ Gyu-Sub Lee-Dept. of Electrical and Computer Engineering, Seoul National University (SNU), Seoul, Republic of Korea and Seoul National University Electric Power Research Institute (SEPRI),


 Power Transfer Stability Analysis of Grid Forming Converters SCR에 따른 그리드 포밍 인버터의 전력 전달 안정성 분석 Seong-Jeon Lee ․ Joosik Kwak ․ Gyu-Sub Lee 이성전* ․ 곽주식** ․ 이규섭†

 Abstract
 With the growth of renewable energy sources (RES) and energy storage systems (ESS), the number of distributed generators (DGs) integrated into power systems via voltage source converters (VSCs) has been increasing. VSCs are operated either in grid-following (GFL) or grid-forming (GFM) control modes. While the GFM mode offers the advantage of not requiring a phase-locked loop (PLL) for grid synchronization, it exhibits a stability issue when the grid impedance decreases. To analyze the stability concerns of GFM inverters, a PSCAD simulation-based study was conducted considering the short-circuit ratio (SCR) and the grid impedance X/R ratio (the ratio of inductive to resistive impedance). The results demonstrate that GFM inverters become more unstable as the SCR increases and the X/R ratio decreases. Key Words Grid forming converter, Short circuit ratio, Stability analysis, Voltage sourced converter, X/R Ratio † Corresponding Author : Dept. of Electrical and Computer Engineering, Seoul National University (SNU), Seoul, Republic of Korea and Seoul National University Electric Power Research Institute (SEPRI), Seoul, Republic of Korea. E-mail : lgs1106@snu.ac.kr https://orcid.org/0000-0002-6313-4685 * Dept. of Electrical and Computer Engineering, Seoul National University (SNU), Seoul, Republic of Korea. https://orcid.org/0009-0003-1996-001X ** Korea Electric Power Corporation Research Institute, Republic of Korea. Received : Oct. 30, 2024 Revised : Apr. 29, 2025 Accepted : Aug. 14, 2025 Copyright ⓒ The Korean Institute of Electrical Engineers This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. ISSN 1975-8359 [Print] / ISSN 2287-4364 [Online]

VIEW ORIGINAL PAPER:

 VERSION TRANSLATED FROM KOREAN WITH GOOGLE:

PORTUGUESE VERSION TRANSLATED FROM KOREAN WITH GOOGLE