This is the Part 2 of the Typhoon seminar by Dr. Ćuk at APEC 2016: WHAT COMES FIRST: DEVICES OR TOPOLOGY?, which answered clearly that the CONVERTER TOPOLOGY is by far the most important as switching devices GOOD or BAD performance depends EXCLUSIVELY and SOLELY on the converter topology used and not on SWITCHING DEVICES used! The conventional synchronous buck converter is compared to Ćuk-buck2 converter for 48V to 1 V conversion to demonstrate the point! The waveforms generated on the site by Typhoon-HIL simulator for Ćuk-buck2 converter confirm that synchronous buck converter is patently unsuitable for large voltage conversion step-downs irrespective of the device technology (yes, including the GaN devices, too!) due to extremely bad utilization of the switches! Synchronous rectifier switch needed in buck converter is rated for 100 V, 100 A or 10kW! Ćuk-buck2 converter uses only 2 V, 100 A rated device or 200 W. In addition, that switch turns-ON and turns-OFF at ZERO current compared to 100 A of the synchronous buck. Even magnetics is four times reduced! CONVERTER TOPOLOGIES DO MATTER!
No Blog Eletrônica de Potência você encontrará informações sobre teses,artigos,seminarios,congressos,tecnologias,cursos,sobre eletrônica potência. “TEMOS O DESTINO QUE MERECEMOS. O NOSSO DESTINO ESTA DE ACORDO COM OS NOSSOS MERITOS” ALBERT EINSTEIN. Imagination is more important than knowledge, for knowledge is limited while imagination embraces the entire world. EL FUTURO SE CONSTRUYE HOY,EL SUCESSO NO ES FRUTO DE LA CASUALIDAD,SE HUMILDE ,APRENDE SIEMPRE CADA DIA.
AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL
"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"
segunda-feira, 11 de abril de 2016
TYPHOON SEMINAR by Dr. Ćuk at APEC 2016-ĆUK-BUCK2 TOPOLOGY BEST FOR ALL SWITCHING DEVICES! Part 2-
This is the Part 2 of the Typhoon seminar by Dr. Ćuk at APEC 2016: WHAT COMES FIRST: DEVICES OR TOPOLOGY?, which answered clearly that the CONVERTER TOPOLOGY is by far the most important as switching devices GOOD or BAD performance depends EXCLUSIVELY and SOLELY on the converter topology used and not on SWITCHING DEVICES used! The conventional synchronous buck converter is compared to Ćuk-buck2 converter for 48V to 1 V conversion to demonstrate the point! The waveforms generated on the site by Typhoon-HIL simulator for Ćuk-buck2 converter confirm that synchronous buck converter is patently unsuitable for large voltage conversion step-downs irrespective of the device technology (yes, including the GaN devices, too!) due to extremely bad utilization of the switches! Synchronous rectifier switch needed in buck converter is rated for 100 V, 100 A or 10kW! Ćuk-buck2 converter uses only 2 V, 100 A rated device or 200 W. In addition, that switch turns-ON and turns-OFF at ZERO current compared to 100 A of the synchronous buck. Even magnetics is four times reduced! CONVERTER TOPOLOGIES DO MATTER!
Assinar:
Postar comentários (Atom)
Nenhum comentário:
Postar um comentário