AUTOR DO BLOG ENG.ARMANDO CAVERO MIRANDA SÃO PAULO BRASIL

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS DO MAL"

"OBRIGADO DEUS PELA VIDA,PELA MINHA FAMILIA,PELO TRABALHO,PELO PÃO DE CADA DIA,PROTEGENOS  DO MAL"

“SE SEUS PROJETOS FOREM PARA UM ANO,SEMEIE O GRÂO.SE FOREM PARA DEZ ANOS,PLANTE UMA ÁRVORE.SE FOREM PARA CEM ANOS,EDUQUE O POVO.”

“Sixty years ago I knew everything; now I know nothing; education is a progressive discovery of our own ignorance. Will Durant”

https://picasion.com/
https://picasion.com/

terça-feira, 3 de dezembro de 2019

STRATEGIES TO DEAL WITH GROUND FAULTS IN GRID-CONNECTED TRANSFORMERLESS PHOTOVOLTAIC CONVERTERS WITH BATTERY ENERGY STORAGE SYSTEM Lucas V. Bellinaso, Ricardo S. Figueredo, Marcelo P. Almeida, Ricardo J. F. Bortolini, Leandro Michels, Ildo Bet, Roberto Zilles Power Electronics and Control Group of the Federal University of Santa Maria, PHB Eletrônica LTDA, Universidade de São Paulo - USP,Brazil


STRATEGIES TO DEAL WITH GROUND FAULTS IN GRID-CONNECTED TRANSFORMERLESS PHOTOVOLTAIC CONVERTERS WITH BATTERY ENERGY STORAGE SYSTEM
 Lucas V. Bellinaso, Ricardo S. Figueredo, Marcelo P. Almeida, Ricardo J. F. Bortolini, Leandro Michels, Ildo Bet, Roberto Zilles
Power Electronics and Control Group of the Federal University of Santa Maria,
PHB Eletrônica LTDA,
Universidade de São Paulo - USP,Brazil

 Abstract – Grid-connected photovoltaic systems with energy storage, also called PV hybrid mini-grid system (PVHMS), operate in both grid-tied and stand-alone modes and are expected to play an important role in distributed generation. Transformerless photovoltaic converters are most preferred for these systems due to their higher conversion efficiency in comparison to insulated converters, increasing autonomy of the battery energy storage system (BESS). Safety in transformerless photovoltaic converters is a critical issue due to parasitic capacitance between PV modules and ground that could result in high leakage current. Existing safety requirements for grid-tied PV inverters may not be sufficient for PVHMS converters since they have multiple leakage current paths. This study analyzes some leakagecurrent- related faults on transformerless PVHMS converters, and proposes relay opening sequences to avoid unnecessary interruptions of power supply for the local loads. The following situations are analyzed: i) fault at dc side, ii) fault at ac load side, and iii) commutation between on-grid and off-grid operation modes. These faults have been studied for a transformerless PVHMS converter with a single dc-ac stage. Experimental results are presented to validate the proposed schemes and a table summarizing the proposals is presented. Keywords – Electric shock, Photovoltaic power systems, Power electronics, Protective relaying, Uninterruptible power systems.
LINK:https://sobraep.org.br/site/uploads/2019/09/rvol24no03-10-0015-314-322.pdf

Nenhum comentário:

Postar um comentário